Technical Data
Technical data | AP-120 |
Recommended area | 140 m² |
Air volume | 1,200 m³/h |
Operating voltage | 230 V |
Frequency | 50 Hz |
Connection cable | 1.8 m / 3.0 m / 4.0 m or desired length (specify when ordering) |
Connector plug | CEE 7/7 (Schuko plug) |
Motor | EC motor (electronic control) |
Dimensions | 1240 x 575 x 325 mm |
Weight | 40.2 kg |
Operating temperature | 5 °C – 40 °C |
Relative humidity | < 80 % |
Operation | Guard switch on rear side |
Pre-filter | yes |
HEPA-filter | H14 Medical |
Dust class | H14 – according to DIN EN 1822 (ISO 45H filter ISO 29463) H – according to DIN EN 60335-2-69 F7 – according to DIN EN 779:2002 |
Activated carbon filter | yes, honeycomb |
UV lamp | yes (254 nm) |
Photocatalyst | yes (TiO2) |
Plasma | yes |
Air duct | Inlet rear / outlet front |
Change interval UV lamp | approx. 8000 h (timer) |
Test reports | CE, ROHS, EMC, official biologic and filter function report of GDIM |
Viruses / Bacteria tested (Details see Report) | Viren H1N1, H3N2 and Bacteria |
Filter test | PM2.5 / PM0.3 |
Housing | White, galvanized steel, lacquered |
Volume (measured, 1m) | |
Level L: | 35 dB |
Level M: | 43 dB |
Level H: | 59 dB |
Volume (measured, 3m) | |
Level L: | 34 dB |
Level M: | 39 dB |
Level H: | 53 dB |
Air volume – motor speed | |
Level L: | 805 m³ – 435 U/min |
Level M: | 972 m³ – 546 U/min |
Level H: | 1290 m³ – 724 U/min |
Power consumption UV lamp off: | |
Standby: | n/a |
Level L: | 40,5 W |
Level M: | 61,8 W |
Level H: | 105 W |
Power consumption UV lamp on: | + 40 W |
Note:
Technical data determined in laboratories of AW Laboratories. Air volume measured with new filters. Volume measured in normal application environment, different room acoustics due to wall coverings and interior furnishings, and different measurement methods used in the industry may affect the measurement result.